Quay lại Purolite
Purolite logo

Tóm tắt tài liệu kỹ thuật

Purolite C100H

PDF datasheet mirror for Purolite C100H (Purolite). Verify with OEM before design.

Summary

Product identification

  • Product Name: Purolite C100H
  • Product Type: Polystyrenic Gel, Strong Acid Cation Resin, Hydrogen form

TYPICAL PHYSICAL & CHEMICAL CHARACTERISTICS

  • Polymer Structure: Gel polystyrene crosslinked with divinylbenzene
  • Appearance: Spherical Beads
  • Functional Group: Sulfonic Acid
  • Ionic Form: H⁺ form
  • Total Capacity: 2.0 eq/L (43.7 Kgr/ft³) (Na⁺ form)
  • Moisture Retention: 51 - 55 % (H⁺ form)
  • Particle Size Range: 300 - 1200 µm
    • < 300 µm (max.): 1 %
  • Uniformity Coefficient (max.): 1.7
  • Reversible Swelling, Na⁺ → H⁺ (max.): 8 %
  • Specific Gravity: 1.2
  • Shipping Weight (approx.): 745 - 785 g/L (46.6 - 49.1 lb/ft³)
  • Temperature Limit: 120 °C (248.0 °F)

SYSTEMS

  • Coflow regenerated systems
  • Conventional counterflow systems

TYPICAL PACKAGING

  • 1 ft³ Sack
  • 25 L Sack
  • 5 ft³ Drum (Fiber)
  • 1 m³ Supersack
  • 42 ft³ Supersack

PRINCIPAL APPLICATIONS

  • Demineralization - Industrial

ADVANTAGES

  • Excellent physical and chemical stability
  • Good kinetic performance
  • High operating capacity

Hydraulic Characteristics

BACKWASH

During up-flow backwash, the resin bed should be expanded in volume between 50 and 70% for at least 10 to 15 minutes. When first putting into service, approximately 30 minutes of expansion is usually sufficient. Bed expansion increases with flow rate and decreases with influent fluid temperature. Avoid loss of resin through the top of the vessel by over expansion.

PRESSURE DROP

The pressure drop across a bed of ion exchange resin depends on particle size distribution, bed depth, voids volume, flow rate, and viscosity. Factors such as filtered particulate matter, abnormal resin compressibility, or incomplete bed classification will increase head loss. Service flow rates may vary from 10 to 40 BV/h depending on water quality, application, and plant design.


Disclaimer: This extracted summary may not include all figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.