Quay lại Lanxess LEWATIT
Lanxess logo

Tóm tắt tài liệu kỹ thuật

LEWATIT® NM 60 SG

PDF datasheet mirror for LEWATIT® NM 60 SG (Lanxess LEWATIT). Verify with OEM before design.

Summary

Product Identification

Lewatit® NM 60 SG is a heterodisperse, gel type, high capacity, high purity mixed ion exchange resin. It is prepared with a 1:1 chemically equivalent ratio of cation to anion resin.

This product is designed for non-regenerable applications.

Operating Limits

  • Stability pH range: 0-14
  • Operating temperature: max. 40 °C
  • Operating pH range during exhaustion: 0-14
  • Max. pressure loss during operation: 200 kPa

Feed Water

  • Bed depth for single column: min. 600 mm
  • Specific pressure loss (15°C): 1.5 kPa*h/m²
  • Specific flow rate: max. 50 BV/h

Product Water Quality

  • Mixed bed test (column capacity) endpoint: min. 0.02 MOhm*cm resistivity
  • Ultrapure water rinse test (resistivity) after 80 BV: min. 18 MOhm*cm
  • Ultrapure water rinse test delta TOC after 80 BV: max. 5 ppb

Electrical

  • Not specified.

Mechanical / Hydraulic

  • Common Description: H⁺/OH⁻ functional group, Quaternary ammonium/sulfonic acid type, Styrenic matrix, Gel structure.
  • Appearance: Dark brown / Yellow translucent
  • Uniformity coefficient: max. 1.8
  • Effective size (d10): 0.40-0.65 mm
  • Mixed bed test (column capacity): min. 0.55 eq/L
  • Bulk density for shipment (+/- 5%): 690 g/L
  • Density: approx. 1.1 g/mL
  • Water retention (delivery form): approx. 50-60 % by weight
  • Volume change (during exhaustion): max. approx. -15 %

Storage and Handling

  • Storage time (after delivery): max. 1 year
  • Storage temperature range: -20 - +40 °C
  • Recommended storage conditions: Above freezing point of water, under roof, in dry conditions, without direct sunlight.
  • Handling if frozen: Allow to thaw gradually at ambient temperature before handling or use. Do not accelerate thawing.
  • Packaging stability: Limited to 24 months under recommended storage conditions.
  • Safety precautions: Avoid contact with strong oxidants like nitric acid. Observe the Safety Data Sheet.
  • Disposal: Follow European waste nomenclature in the European Community.

Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.