LEWATIT® MonoPlus M 500

PDF datasheet mirror for LEWATIT® MonoPlus M 500 (Lanxess LEWATIT). Verify with OEM before design.

Summary

Product identification

  • Product name: Lewatit® MonoPlus M 500
  • Type: Strongly basic, gelular anion exchange resin
  • Bead type: Uniform size (monodisperse)
  • Matrix: Styrene-divinylbenzene copolymer
  • Functional group: Quaternary ammonium, Type 1
  • Common description: Cl⁻
  • Delivery form: Gel
  • Appearance: Yellow, translucent

Applications

  • Demineralization of water for industrial steam generation (e.g., Lewatit® WS System, Lewatit® Liftbed System, Lewatit® Rinsebed System)
  • Polishing in combination with Lewatit® MonoPlus S 108 H in a Lewatit® Multistep System

Key Features

  • High exchange flow rates during regeneration and loading
  • Good utilization of total capacity
  • Low demand for rinse water
  • Homogenous throughput of regenerants, water, and solutions, resulting in a homogenous working zone
  • Nearly linear pressure drop gradient, allowing for higher bed depth operation

Specified Data

  • Uniformity coefficient: max. 1.1
  • Mean bead size (d₅₀): 0.62 (±0.05) mm
  • Total capacity (delivery form): min. 1.3 eq/L

Typical Physical and Chemical Properties

  • Bulk density (for shipment): 690 g/L (±5%)
  • Density: approx. 1.08 g/mL
  • Water retention (delivery form): approx. 48 - 55 % (by weight)
  • Volume change (Cl⁻ to OH⁻): max. approx. 24 %
  • Stability pH range: 0 - 14
  • Storage time (after delivery): max. 2 years
  • Storage temperature range: -20 - +40 °C

Operation

  • Operating temperature: max. 70 °C
  • Operating pH range (during exhaustion): 0 - 12
  • Bed depth (single column): min. 800 mm
  • Backwash bed expansion (per m/h at 20°C): 11 %
  • Specific pressure loss (at 15°C): 1 kPa*h/m²
  • Max. pressure loss (during operation): 200 kPa
  • Specific flow rate: max. 60 BV/h

Regeneration

  • Regeneration chemical: NaOH
  • NaOH regeneration concentration: approx. 2 - 6 wt. %
  • NaOH regeneration quantity (co-current): min. 80 g/L resin
  • NaOH regeneration quantity (counter-current): min. 50 g/L resin
  • Regeneration contact time: min. 20 minutes
  • Slow rinse (at regeneration flow rate): min. 2 BV
  • Fast rinse (at service flow rate): min. 2 BV