Summary

Product identification

Lewatit® MDS 4368 is a food-grade, macroporous anion exchange resin of medium basicity. It is based on polystyrene, bead-shaped, and contains tertiary and quaternary amino groups. Its special bead size distribution is suitable for chromatographic separation, such as the separation of organic acids from sugar solutions.

Physical and Chemical Properties

  • Ionic form as shipped: free base/Cl⁻
  • Functional group: tertiary/quaternary amine
  • Matrix: crosslinked polystyrene
  • Structure: macroporous
  • Appearance: beige
  • Uniformity Coefficient: max. 1.1
  • Bead size: > 90 % between 0.30 - 0.38 mm
  • Bulk density: 665 g/l (± 5 %)
  • Density: approx. 1.04 g/ml
  • Water retention: 59 - 64 wt. %
  • Total capacity: min. 1.4 eq/l
  • Volume change (delivered → Cl⁻): typical 26 vol. %
  • Volume change (operational swelling): typical 12 vol. %
  • Stability (pH range): 0 - 14
  • Stability (temperature range): -20 - 100 °C
  • Storability (product): max. 2 years
  • Storability (temperature range): -20 - 40 °C

Recommended Operating Conditions

  • Operating temperature: max. 70 °C
  • Operating pH range: 0 - 8
  • Bed depth: min. 800 mm
  • Specific pressure drop (at viscosity 1 mPa·s): approx. 2.1 kPa·h/m²
  • Pressure drop: max. 250 kPa
  • Linear velocity (backwash, 20 °C): approx. 1 m/h
  • Bed expansion (backwash, 20 °C): approx. 70 % per m/h
  • Freeboard (backwash): 80 - 100 vol. % (external / internal)

Additional Information & Regulations

  • Safety precautions: Strong oxidants, such as nitric acid, can cause violent reactions with ion exchange resins. Observe the safety data sheet.
  • Disposal: In the European Community, ion exchange resins must be disposed of according to the European waste nomenclature.
  • Storage: Recommended storage is above the freezing point of water, under roof, in dry conditions, and away from direct sunlight. If the resin freezes, allow it to thaw gradually at ambient temperature without mechanical handling.