Tóm tắt tài liệu kỹ thuật
LEWATIT® MDS 1368 Ca / 350
PDF datasheet mirror for LEWATIT® MDS 1368 Ca / 350 (Lanxess LEWATIT). Verify with OEM before design.
Summary
Product identification
- Product name: LEWATIT® MDS 1368 Na 350
- Common Description: Food grade, gel-type, monodisperse, strongly acidic cation exchange resin based on a styrene-divinylbenzene copolymer.
- Functional group: Sulfonic acid
- Matrix: Styrenic
- Structure: Gel
- Appearance: Light brown, transparent
- Delivery form: Na⁺
Specified Data
- Uniformity coefficient: max. 1.15
- Mean bead size (d₅₀): 0.33 - 0.39 mm
- Total capacity (H⁺ form): min. 1.8 eq/L
Typical Physical and Chemical Properties
- Bulk density for shipment (+/- 10%): 820 g/L
- Density (approx.): 1.24 g/mL
- Water retention (H⁺ form) (approx. weight %): 47-53 %
- Stability pH range: 5-14
- Stability temperature range: 1-120 °C
- Storage time (after delivery) (min.): 0.5 years
- Storage temperature range: -20 - +40 °C
Operation
- Operating temperature (max.): 120 °C
- Operating pH range during exhaustion: 0-14
- Bed depth for single column (min.): 800 mm
- Backwash bed expansion per m/h (20°C): 15 %
- Specific pressure loss (15°C): 4 kPa*h/m²
- Max. pressure loss during operation: 200 kPa
Additional Information & Regulations
- Safety precautions: Strong oxidants, e.g. nitric acid, can cause violent reactions if they come into contact with ion exchange resins.
- Toxicity: The safety data sheet must be observed.
- Disposal: In the European Community, ion exchange resins have to be disposed of according to the European waste nomenclature.
- Storage: Recommended to store at temperatures above the freezing point of water, under roof, in dry conditions without direct sunlight. If frozen, allow to thaw gradually at ambient temperature.
- Packaging: Packaging stability is limited to 24 months under recommended storage conditions.
Disclaimer: This extraction may miss figures, footnotes, or revisions; contractual data must match the OEM PDF revision used on the project.