Quay lại Lanxess LEWATIT
Lanxess logo

Tóm tắt tài liệu kỹ thuật

LEWATIT® K 7367

PDF datasheet mirror for LEWATIT® K 7367 (Lanxess LEWATIT). Verify with OEM before design.

Summary

Product identification

Lewatit® K 7367 is a strongly basic, macroporous anion exchange resin with beads of uniform size (monodisperse) based on a styrene-divinylbenzene copolymer.

Ionic form as shipped: Cl⁻ Functional group: quaternary amine, type I Matrix: crosslinked polystyrene Structure: macroporous Appearance: beige, opaque

Physical and Chemical Properties

  • Total capacity: min. 1.0 eq/l
  • Uniformity Coefficient: max. 1.1
  • Mean bead size: 0.62 (+/- 0.05) mm
  • Bulk density: 620 (+/- 5 %) g/l
  • Density: approx. 1.06 g/ml
  • Water retention: 63 - 68 wt. %
  • Volume change (Cl⁻ --> OH⁻): max. 20 vol. %
  • Stability (pH-range): 0 - 14
  • Storability (years): max. 2
  • Storability (temperature range): -20 - 40 °C

Recommended Operating Conditions

  • Operating temperature: max. 70 °C
  • Operating pH-range: 0 - 12
  • Bed depth: min. 800 mm
  • Specific pressure drop (15 °C): approx. 0.8 kPa*h/m²
  • Pressure drop: max. 300 kPa
  • Linear velocity (operation): max. 60 m/h (100 m/h for polishing)
  • Linear velocity (backwash, 20 °C): approx. 5 m/h
  • Bed expansion (20 °C, per m/h): approx. 18 vol. %
  • Freeboard (backwash, extern / intern): 100 vol. %

Regeneration (NaOH)

Counter current regeneration:

  • Level: approx. 50 g/l
  • Concentration: approx. 2 - 4 wt. %
  • Linear velocity (regeneration): approx. 5 m/h
  • Linear velocity (rinsing): approx. 5 m/h
  • Rinse water requirement (slow / fast): approx. 2.5 BV

Co current regeneration:

  • Level: approx. 100 g/l
  • Concentration: approx. 3 - 5 wt. %
  • Linear velocity (regeneration): approx. 5 m/h
  • Linear velocity (rinsing): approx. 5 m/h
  • Rinse water requirement (slow / fast): approx. 8 BV

Additional Information & Regulations

Safety precautions: Strong oxidants, e.g. nitric acid, can cause violent reactions if they come into contact with ion exchange resins. Observe the safety data sheet.

Storage: Store at temperatures above freezing point, under roof, dry, and out of direct sunlight. If frozen, allow to thaw gradually at ambient temperature before handling or use.

Disclaimer: This extraction may miss figures, footnotes, or revisions; contractual data must match the OEM PDF revision used on the project.