Quay lại Lanxess LEWATIT
Lanxess logo

Tóm tắt tài liệu kỹ thuật

LEWATIT® K 6387

PDF datasheet mirror for LEWATIT® K 6387 (Lanxess LEWATIT). Verify with OEM before design.

Summary

Product identification

Lewatit® K 6387 is a strongly basic, bead-shaped, monodisperse, gelular type-I anion exchange resin based on a styrene-divinylbenzene copolymer. It is specially suitable for:

  • Lifetime extension of acid baths (acid retardation process)
  • Chromatographic separation and ion exclusion processes
  • Demineralization (in hydroxide form) of water and aqueous solutions

Physical and Chemical Properties

  • Ionic form as shipped: Cl⁻
  • Functional group: quaternary amine, type I
  • Matrix: crosslinked polystyrene
  • Structure: gel type beads
  • Appearance: yellow, translucent
  • Uniformity Coefficient: max. 1.1
  • Mean bead size: 0.3 mm (± 0.05)
  • Bulk density: 700 g/l (± 5 %)
  • Density: approx. 1.10 g/ml
  • Water retention: 48 - 55 wt. %
  • Total capacity: min. 1.5 eq/l
  • Volume change (Cl⁻ --> OH⁻): max. 25 vol. %
  • Stability (pH-range): 0 - 14
  • Storability (max years): 2
  • Storability temperature range: -20 - 70 °C

Recommended Operating Conditions

  • Operating temperature:
    • OH⁻ form: max. 70 °C
    • Cl⁻ form: max. 90 °C
  • Operating pH-range: 0 - 12
  • Bed depth (min.): 800 mm
  • Specific pressure drop (15 °C): approx. 2.8 kPa·h/m²
  • Pressure drop (max.): 200 kPa
  • Linear velocity (operation):
    • Water: 5 - 40 m/h
    • Sugar: 1 - 5 m/h
  • Linear velocity (backwash, 20 °C): approx. 7 - 9 m/h
  • Bed expansion (20 °C, per m/h): approx. 25 vol. %
  • Freeboard (backwash, external / internal): 80 - 100 vol. %

Regeneration

  • Regenerant: NaOH or NaCl + NaOH
  • Regeneration level (approx. g/l):
    • NaOH: 50 - 80
    • NaCl + NaOH: 20
  • Concentration (approx. wt. %):
    • NaOH: 4 - 10 %
    • NaCl + NaOH: 1 - 2 %
  • Linear velocity (regeneration): approx. 5 m/h
  • Linear velocity (rinsing): approx. 5 m/h
  • Rinse water requirement (slow / fast): approx. 4 BV

Additional Information & Regulations

  • Safety precautions: Strong oxidants (e.g., nitric acid) can cause violent reactions. Observe the safety data sheet.
  • Disposal: Dispose of according to European waste nomenclature.
  • Storage: Store above freezing point, under roof, dry, out of direct sunlight. If frozen, thaw gradually at ambient temperature.

Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

Lenntech datasheet mirror

Nội dung tổng hợp từ tài liệu kỹ thuật công khai nhằm tra cứu và so sánh sơ bộ. Bản tóm tắt không thay thế bảng dữ liệu hiện hành được nhà sản xuất chứng nhận. Kiểm tra phiên bản và giới hạn thiết kế trước khi sử dụng.