Tóm tắt tài liệu kỹ thuật
LEWATIT® K 2621
PDF datasheet mirror for LEWATIT® K 2621 (Lanxess LEWATIT). Verify with OEM before design.
Summary
Product identification
- Product Name: Lewatit® K 2621
- Common Description: Strongly acidic, macroporous, polymer-based ion exchange resin in spherical bead form with sulfonic acid groups.
- Functional group: sulfonic
- Matrix: styrenic
- Structure: macroporous
- Appearance: beige, opaque
- Delivery form: H⁺
Applications
This resin is ideally suited for processing organic liquid media and is particularly used in:
- Production of the gasoline additives MTBE, ETBE and TAME
- Phenol alkylation with olefins
- Hydration of olefins
- Esterifications and etherifications
- Condensations
- Alkylation reactions
Operating limits
- Operating temperature: max. 125 °C
- Operating pH range during exhaustion: 0-14
- Bed depth for single column: min. 1000 mm
- Max. pressure loss during operation: 250 kPa
- Stability temperature range: 1-125 °C
Physical and Chemical Properties
- Uniformity coefficient: max. 1.6
- Range of size for >90 vol% of all beads: 0.40-1.25 mm
- Effective size (d₁₀): 0.50-0.62 mm
- Total capacity (delivery form): min. 1.4 eq/L
- Bulk density for shipment (+/- 5%): 700 g/L
- Density: approx. 1.14 g/mL
- Water retention (delivery form): approx. 57-63 % weight
- Surface BET: approx. 40 m²/g
- Pore volume: approx. 0.6 cm³/g
- Pore diameter: approx. 65 nm
Storage and Handling
- Storage temperature range: -20 - +40 °C
- Recommended storage conditions: Above the freezing point of water, under roof, in dry conditions without direct sunlight.
- Packaging stability: Limited to 24 months under recommended storage conditions. It is recommended to use the product within this timeframe, otherwise check packaging condition regularly.
- Frozen resin handling: If resin becomes frozen, it should not be mechanically handled and left to thaw gradually at ambient temperature. It must be completely thawed before handling or use. Do not accelerate thawing.
- Safety precautions: Strong oxidants, e.g., nitric acid, can cause violent reactions. Observe the safety data sheet.
- Disposal: According to the European waste nomenclature.
Disclaimer This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.