Tóm tắt tài liệu kỹ thuật
LEWATIT® FO 36
PDF datasheet mirror for LEWATIT® FO 36 (Lanxess LEWATIT). Verify with OEM before design.
Summary
Product identification
- Product Name: Lewatit® FO 36
- Type: Macroporous, monodispersed, polystyrene-based resin for selective adsorption of oxoanions.
- Functional Group: FeO(OH) (iron oxide film on polystyrene matrix)
- Ionic Form as Shipped: Neutral
- Structure: Macroporous
- Appearance: Brown, opaque
Applications
Lewatit® FO 36 is suitable for:
- Arsenic removal from drinking water.
- Arsenic removal from ground water and waste water.
- Arsenic removal from process solutions, even in the presence of high salt concentrations.
It can remove arsenic to concentrations significantly lower than 10 µg/l. The resin can also selectively adsorb other species like HPO₄²⁻, HSiO₃⁻, HSbO₄²⁻, HVO₄²⁻, SCN⁻, and naturally occurring organic matter, tannins, lignins, uranium complexes, and chromate.
Operating Limits
- Minimum pH Exposure: 4 (to prevent dissolution of iron oxide)
- Stability pH Range: 4 - 14
Physical and Chemical Properties
- Uniformity Coefficient: max. 1.1
- Mean Bead Size: 0.34 - 0.38 mm
- Share of Beads in Range (Mean Bead Size +/- 0.05 mm): > 90 vol. %
- Bulk Density: 0.765 kg/l
- Density: approx. 1.25 g/ml
- Specific Pressure Drop (15 °C): approx. 1.97 kPa·h/m²
- Bed Expansion (20 °C, per m/h): approx. 9.8 vol. %
- Water Retention: 53 - 58 wt. %
- Storability: max. 2 years
- Storage Temperature Range: -20 to +40 °C
Recommended Operating Conditions
- Operating Temperature: max. 60 °C
- Operating pH Range: 4 - 11
- Bed Depth: min. 1000 mm
- Pressure Drop: max. 250 kPa
- Linear Velocity (Operation): max. 30 m/h
- Linear Velocity (Backwash, 20 °C): approx. 4 m/h
- Freeboard (Backwash, external / intern): 100 vol. %
- Regenerant: NaOH + NaCl (mass ratio 1:1)
- Co-current Regeneration Level: approx. 40 + 40 g/l
- Co-current Regeneration Concentration: approx. 2 + 2 wt. %
- Linear Velocity (Regeneration): approx. 5 m/h
- Rinse Water Requirement (Slow / Fast): approx. 5 BV
- Linear Velocity (Rinsing): approx. 5 m/h
- Conditioning: HCl or H₂SO₄
- Conditioning pH (min.): 4
- Conditioning Flow Direction: Upflow
- Linear Velocity (Conditioning): approx. 4 m/h
- Conditioning Duration: approx. 12 h
Recommended Start-up Conditions (for drinking water and food applications)
- Linear Velocity: approx. 5 m/h
- Rinse Water Requirement: approx. 2 BV
Additional Information
- Compliance: Complies with European Resolution ResAP (2004)3 and AFNOR test T 90-601 for Total Organic Carbon (TOC) release after pre-treatment.
- Safety: Observe safety data sheet. Avoid contact with strong oxidants. Store above freezing point, dry, and out of direct sunlight.
- Disposal: According to European waste nomenclature.
Disclaimer Extraction may miss figures, footnotes, or revisions; contractual data must match the OEM PDF revision used on the project.
Official datasheet (PDF)
Nội dung tổng hợp từ tài liệu kỹ thuật công khai nhằm tra cứu và so sánh sơ bộ. Bản tóm tắt không thay thế bảng dữ liệu hiện hành được nhà sản xuất chứng nhận. Kiểm tra phiên bản và giới hạn thiết kế trước khi sử dụng.