Quay lại Lanxess LEWATIT
Lanxess logo

Tóm tắt tài liệu kỹ thuật

LEWATIT® ASB 1 OH

PDF datasheet mirror for LEWATIT® ASB 1 OH (Lanxess LEWATIT). Verify with OEM before design.

Summary

Product identification

Lewatit® ASB-1 OH is a premium grade, gel, strong base, Type 1, anion exchange resin based on a styrene/DVB polymer. It is supplied in the hydroxide form (OH⁻) and is also available in the chloride form as Lewatit® ASB-1. It is prepared with a high degree of conversion to the hydroxide form and a minimum amount of fines for low pressure losses.

Applications

Lewatit® ASB-1 OH is especially suited for:

  • High purity separate bed applications
  • Mixed bed applications
  • Applications where silica reduction in the final treated water is critical.

Physical and Chemical Properties

  • Ionic form as shipped: OH⁻
  • Functional group: Quaternary amine
  • Matrix: DVB / Styrene
  • Structure: Gel
  • Appearance: Clear translucent
  • Uniformity Coefficient: max. 1.6
  • Bead size: 0.3 - 1.25 mm
  • Effective size: 0.52 (+/- 0.06) mm
  • Bulk density: 655 (+/- 5 %) g/l
  • Density: approx. 1.08 g/ml
  • Water retention: 55 - 60 wt. %
  • Total capacity: min. 1.15 eq/l
  • Volume change (Cl⁻ --> OH⁻): max. 20 vol. %
  • Stability (pH-range): 0 - 14
  • Stability (temperature range): 1 - 60 °C

Storability

  • Duration: max. 6 months
  • Temperature range: 4 - 24 °C

Recommended Operating Conditions

  • Operating temperature: max. 60 °C
  • Operating pH-range: 0 - 14
  • Bed depth: min. 800 mm
  • Pressure drop: max. 200 kPa (200 psi/ft bed)
  • Linear velocity (exhaustion): 5 - 25+ m/h
  • Bed expansion (backwash at 20 °C): approx. 4 % per m/h
  • Freeboard (backwash): 80 - 100 vol. %
  • Volumetric flow rate (exhaustion): 8 - 32+ BV/h

Regeneration

  • Regenerant type: NaOH
  • Regenerant level: approx. 64 - 240 g/l
  • Regenerant concentration: approx. 3 - 6 wt. %
  • Linear velocity (regeneration): approx. 1 - 10 m/h
  • Linear velocity (rinse, slow / fast): 1 - 10 / 12 - 25 m/h
  • Volumetric flow rate (regeneration): 1.5 - 4 BV/h
  • Volumetric flow rate (rinse, slow / fast): approx. 1.5 - 4 / 8 - 32 BV/h
  • Rinse water requirement (slow / fast): approx. 1 - 2.5 / 3 - 8 BV

Additional Information

  • Safety: Avoid contact with strong oxidants. Observe the safety data sheet for product description, transport, storage, handling, safety, and ecology.
  • Disposal: Dispose of according to the European waste nomenclature.
  • Storage: Store above freezing point of water, under roof, in dry conditions, without direct sunlight. If frozen, allow to thaw gradually at ambient temperature before handling or use.

Disclaimer: This extraction may miss figures, footnotes, or revisions; contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

Lenntech datasheet mirror

Nội dung tổng hợp từ tài liệu kỹ thuật công khai nhằm tra cứu và so sánh sơ bộ. Bản tóm tắt không thay thế bảng dữ liệu hiện hành được nhà sản xuất chứng nhận. Kiểm tra phiên bản và giới hạn thiết kế trước khi sử dụng.