Quay lại DuPont
DuPont logo

Tóm tắt tài liệu kỹ thuật

AmberSep IRC748 UPS

PDF datasheet mirror for AmberSep IRC748 UPS (DuPont). Verify with OEM before design.

Summary

Product Identification

  • Product Name: AmberSep™ IRC748 UPS Chelating Resin
  • Type: Chelant
  • Matrix: Macroporous
  • Copolymer: Styrene-divinylbenzene
  • Functional Group: Iminodiacetic acid
  • Physical Form: Beige, hard, opaque, spherical beads

Applications

  • Chlor-alkali (brine purification)
  • Electronics (printed wiring boards)
  • Electroplating
  • Process streams (trace metal removal)
  • Hydrometallurgy (recovery of heavy metals from leach streams)

Typical Properties

  • Ionic Form as Shipped: Na⁺
  • Total Exchange Capacity: 1.35 eq/L
  • Dry Weight Capacity: ≥ 4.45 eq/kg
  • Water Retention Capacity: 60 – 69%
  • Particle Size:
    • Particle Diameter: 575 ± 75 µm
    • Uniformity Coefficient: ≤ 1.2
    • < 300 µm: ≤ 1.0%
    • 1000 µm: ≤ 5.0%

  • Stability (Swelling H⁺ → Na⁺): 30%
  • Shipping Weight: 750 g/L

Suggested Operating Conditions

  • Maximum Operating Temperature: 90°C (194°F)
  • Operating pH Range: 1.5 – 14 (depends on the application)
  • Flowrates:
    • Service: 6 – 32 BV*/h (0.75 – 4 gpm/ft³)
    • Regeneration: 2 – 4 BV/h (0.25 – 0.50 gpm/ft³)
  • Regenerant:
    • HCl: 5 – 10%
    • H₂SO₄: 5 – 10%
  • Conversion to Na⁺ form: 1 – 4% NaOH at flowrate of 2 – 4 BV/h

* 1 BV (Bed Volume) = 1 m³ solution per m³ resin or 7.5 gal per ft³ resin.

Hydraulic Characteristics

Bed expansion and pressure drop data are provided as figures in the original document, with equations for calculating flowrates at different temperatures.

Application Information

The resin exhibits selectivity for metal ions in the following general order: Fe³⁺ > Hg²⁺ > Cu²⁺ > Pb²⁺ > Ni²⁺ > Zn²⁺ > Cd²⁺ > Co²⁺ > Fe²⁺ > Mn²⁺ > Ca²⁺ >> Na⁺

The affinity for H⁺ at pH 4 is situated between Cu²⁺ and Pb²⁺. For metals with selectivities less than Cu²⁺, the resin should be in the salt form (e.g., Na⁺ form) to minimize metal leakage. At pH 2, the resin will be extensively in the H⁺ form and will efficiently remove Fe³⁺, Hg²⁺, and Cu²⁺.

Selectivity at various pH conditions is presented in tables within the original document. Minimum pH values are recommended for various cations to ensure effective operation.

Disclaimer This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.