Summary

Product identification

  • Product Name: AmberLite™ XAD™ 18 Polymeric Adsorbent
  • Description: Macroporous, non-ionic, highly crosslinked polystyrenic adsorbent resin.
  • Form Supplied: White, opaque, spherical beads in fully hydrated, wetcake form, imbibed with sodium chloride (NaCl) and sodium carbonate (Na₂CO₃).

Applications

  • Recovery and purification of antibiotics, natural products, amino acids, and proteins.
  • Designed for biopharmaceutical molecule separation with high capacity and selectivity.

Typical Properties

Physical Properties

  • Matrix: Macroporous, crosslinked DVB
  • Type: Adsorbent
  • Functional Group: None
  • Physical Form: White, opaque, spherical beads
  • Nitrogen BET Surface Area: ~700 m²/g
  • Average Pore Diameter: ~150 Å
  • Particle Size:
    • Particle Diameter: 425 ± 50 μm
    • Uniformity Coefficient: ≤ 1.7 %
    • Fines (< 212 µm): ≤ 2 %
  • Swelling (in solvent):
    • Methanol: 15 – 20 %
    • 2-Propanol: 15 – 20 %
    • Acetone: 10 – 15 %
  • Density:
    • Particle Density: 1.03 g/mL
    • Shipping Weight: 650 g/L

Chemical Properties

  • Binding Capacity for Ceph C (1% breakthrough): ≥ 60 g/L

Suggested Operating Conditions

  • Maximum Operating Temperature: 150°C (302°F)
  • pH Range (Stable): 1 – 14
  • Bed Depth (min, Industrial): 1200 mm (3.9 ft)
  • Flowrates:
    • Loading: 0.50 – 2 BV*/h
    • Elution/Desorption: 0.50 – 2 BV/h
    • Regeneration: 0.50 – 2 BV/h
    • Rinse: 0.50 – 2 BV/h
    • *1 BV (Bed Volume) = 1 m³ solution per m³ resin or 7.5 gal per ft³ resin

Regenerants or Eluting Agents

  • Water-miscible organic solvents (methanol, ethanol, isopropanol, acetone, etc.)
  • Alkaline solutions (e.g., 1 N NaOH)
  • Dilute acids (0.1 – 0.5% HCl)
  • Dilute oxidizing agents (< 0.5%) such as peroxide
  • Hot nitrogen or steam

Hydraulic Characteristics

  • Figures showing estimated bed expansion (backwash) and pressure drop (service flowrate) as a function of flowrate are provided in the original document.

Pretreatment

  1. Salt Wash: Wash the resin in the column with deionized water at 2 – 3 BV/h until salt levels are sufficiently low.
  2. Solvent Equilibration:
    • Equilibrate with 8 BV of 100% organic solvent (acetonitrile, acetone, ethanol, propanol, or methanol) at a maximum flowrate of 2 BV/h.
    • Equilibrate with 5 BV of a 50% organic solvent/water solution at a maximum flowrate of 1 BV/h.

Disclaimer This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

Lenntech datasheet mirror

Nội dung tổng hợp từ tài liệu kỹ thuật công khai nhằm tra cứu và so sánh sơ bộ. Bản tóm tắt không thay thế bảng dữ liệu hiện hành được nhà sản xuất chứng nhận. Kiểm tra phiên bản và giới hạn thiết kế trước khi sử dụng.