AmberLite HPR4100 Cl

PDF datasheet mirror for AmberLite HPR4100 Cl (DuPont). Verify with OEM before design.

Summary

Product Identification

  • Product Name: AmberLite™ HPR4100 Cl Ion Exchange Resin
  • Type: Uniform Particle Size, Gel, Strong Base Anion (Type II) Exchange Resin
  • Description: Optimized for industrial demineralization, balancing operating performance with cost-effective operation. It offers excellent operating capacity and rinse characteristics, reducing chemical regenerant and rinse water usage while maintaining superior physical stability.
  • Historical Reference: Previously sold as DOWEX MARATHON™ A2 Ion Exchange Resin.

Applications

  • Demineralization for removal of strong and weak acids.
  • Dealkalization.

System Designs

  • Co-current
  • Counter-current / Hold-down
  • Packed beds

Typical Properties

Physical Properties

  • Copolymer: Styrene-divinylbenzene
  • Matrix: Gel
  • Type: Strong base anion, Type II
  • Functional Group: Dimethylethanolammonium
  • Physical Form: White to amber, translucent, spherical beads

Chemical Properties

  • Ionic Form as Shipped: Cl⁻
  • Total Exchange Capacity: ≥ 1.2 eq/L (Cl⁻ form)
  • Water Retention Capacity: 45.0 – 54.0% (Cl⁻ form)

Particle Size

  • Particle Diameter: 550 ± 50 µm
  • Uniformity Coefficient: ≤ 1.1
  • Fines (< 300 µm): ≤ 0.3%
  • Oversized (> 850 µm): ≤ 1.0%

Stability and Density

  • Whole Uncracked Beads: ≥ 95%
  • Swelling (Cl⁻ → OH⁻): 15%
  • Particle Density: 1.10 g/mL
  • Shipping Weight: 690 g/L

Suggested Operating Conditions

  • Temperature Range (OH⁻ form): 5 – 35°C (41 – 95°F)
  • Temperature Range (Cl⁻ form): 5 – 80°C (41 – 176°F)
  • pH Range (Service Cycle): 1 – 14
  • pH Range (Stable): 0 – 14

Hydraulic Characteristics

Estimated bed expansion and pressure drop figures are provided in the original document, illustrating their dependence on backwash flowrate, service flowrate, and temperature.

  • Backwash Expansion Figure 1: Valid for temperatures from 10 – 60°C (50 – 140°F).
  • Pressure Drop Figure 2: Valid for temperatures from 10 – 60°C (50 – 140°F). These are expectations at the start of a service run with clean water.

Product Stewardship and Customer Notice

DuPont emphasizes product stewardship, covering safety, health, and environmental aspects. Customers are encouraged to review manufacturing processes and applications to ensure appropriate and intended use. Safety Data Sheets should be consulted before use.

WARNING: Oxidizing agents, such as nitric acid, can attack organic ion exchange resins and may lead to exothermic reactions. Consult knowledgeable sources before using strong oxidizing agents.


Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

Lenntech datasheet mirror

Nội dung tổng hợp từ tài liệu kỹ thuật công khai nhằm tra cứu và so sánh sơ bộ. Bản tóm tắt không thay thế bảng dữ liệu hiện hành được nhà sản xuất chứng nhận. Kiểm tra phiên bản và giới hạn thiết kế trước khi sử dụng.