Tóm tắt tài liệu kỹ thuật
AmberLite HPR1300 H
PDF datasheet mirror for AmberLite HPR1300 H (DuPont). Verify with OEM before design.
Summary
Product identification
AmberLite™ HPR1300 H Ion Exchange Resin is a uniform particle size, gel, strong acid cation exchange resin. It was previously sold as DOWEX MARATHON™ 1300 H Ion Exchange Resin.
Applications
- Demineralization (especially where high oxidant levels or high temperatures on the cation resin are present; single bed industrial demineralization requiring high water purity)
- Condensate polishing
- Mixed bed polishing
System Designs
Compatible with:
- Co-current
- Counter-current / Hold-down
- Layered beds
- Packed beds
- Mixed beds
Typical Properties
Physical Properties
- Copolymer: Styrene-divinylbenzene
- Matrix: Gel
- Type: Strong acid cation
- Functional Group: Sulfonic acid
- Physical Form: Dark brown, translucent, spherical beads
Chemical Properties
- Ionic Form as Shipped: H⁺
- Total Exchange Capacity: ≥ 2.0 eq/L (H⁺ form)
- Water Retention Capacity: 46.0 – 52.0% (H⁺ form)
Particle Size
- Particle Diameter: 650 ± 50 µm
- Uniformity Coefficient: ≤ 1.10
- Fines (< 300 µm): ≤ 0.1%
- Oversized (> 850 µm): ≤ 5.0%
Stability
- Whole Uncracked Beads: ≥ 95%
- Friability: Average ≥ 350 g/bead
- Resilience (> 200 g/bead): ≥ 95%
Swelling
- Na⁺ → H⁺: 7%
Density
- Particle Density: 1.22 g/mL
- Shipping Weight: 785 g/L
Suggested Operating Conditions
- Temperature Range (H⁺ form): 5 – 120°C (41 – 248°F)
- pH Range (Service Cycle): 1 – 14
- pH Range (Stable): 0 – 14
Hydraulic Characteristics
Estimated bed expansion and pressure drop data are available in Figures 1 and 2, respectively, as a function of backwash flowrate, service flowrate, temperature, and time. These figures are valid for temperatures between 10 – 60°C (50 – 140°F).
Product Stewardship and Customer Notice
DuPont emphasizes product stewardship, requiring customers to review manufacturing processes and applications to ensure safe and appropriate use. Consult Safety Data Sheets before use. WARNING: Oxidizing agents like nitric acid can degrade ion exchange resins and may cause exothermic reactions (explosions).
Disclaimer: Extraction may miss figures, footnotes, or revisions; contractual data must match the OEM PDF revision used on the project.
Official datasheet (PDF)
Nội dung tổng hợp từ tài liệu kỹ thuật công khai nhằm tra cứu và so sánh sơ bộ. Bản tóm tắt không thay thế bảng dữ liệu hiện hành được nhà sản xuất chứng nhận. Kiểm tra phiên bản và giới hạn thiết kế trước khi sử dụng.