Summary

Product Identification

  • Product Name: AMBERLITE™ FPX66 Polymeric Adsorbent
  • Description: Macroporous, non-functionalized, adsorbent resin designed for food and biopharmaceutical processing.
  • Type: Adsorbent
  • Copolymer: Crosslinked aromatic polymer
  • Matrix: Macroporous
  • Functional Group: None
  • Physical Form: White, opaque, spherical beads

Applications

  • Food Processing:
    • Decolorization
    • Purification
    • Recovery of high-value materials
  • Biopharmaceutical Processing:
    • Separation of small molecular weight compounds (e.g., antibiotics, vitamins, steroids, amino acids, enzymes, peptides)

Typical Properties

Physical Properties

  • Surface Area (Nitrogen BET): ~700 m²/g
  • Total Pore Volume: ~1.4 cc/g
  • Particle Size:
    • Particle Diameter: 600 – 750 µm
    • Fines (< 300 µm): ≤ 3.0%
    • Oversized (> 1180 µm): ≤ 5.0%
  • Density:
    • Particle Density: 1.015 – 1.025 g/mL
    • Shipping Weight: 680 g/L

Chemical Properties

  • Ionic Form as Shipped: Not applicable
  • Total Exchange Capacity: Not applicable
  • Water Retention Capacity: 60 – 68%
  • DVB Content: ≤ 50 ppb

Suggested Operating Conditions

  • Maximum Operating Temperature: 150°C (302°F)
  • pH Range: 0 – 14
  • Bed Depth, min.: 700 mm (2.3 ft)
  • Flowrates:
    • Loading: 2 – 16 BV*/h (usually)
    • Washing: 1 – 2 BV/h
    • Backwash: See Figure 1 in the original document.
    • Regeneration: 1 – 2 BV/h
    • Rinse: 2 – 16 BV/h
  • Regenerants:
    • Methanol or other water-miscible organic solvents (e.g., ethanol, isopropanol, acetone)
    • Dilute bases and/or dilute acids
    • Hot water or steam for volatile materials

* 1 BV (Bed Volume) = 1 m³ solution per m³ resin or 7.5 gal per ft³ resin.

Hydraulic Characteristics

Estimated bed expansion and pressure drop data are available in the original document's Figures 1 and 2, respectively. These are dependent on flowrate, temperature, and bed condition.

  • Backwash Expansion: Dependent on flowrate and temperature (See Figure 1 in the original document).
  • Pressure Drop: Dependent on service flowrate and temperature (See Figure 2 in the original document).
    • Parameters for Figure 1 (Backwash Expansion): Temperature = 10 – 51.7°C (50 – 125°F)
    • Parameters for Figure 2 (Pressure Drop): Temperature = 4.4 – 65.6°C (40 – 150°F)