Tóm tắt tài liệu kỹ thuật
Proline Promass H 100
PDF datasheet mirror for Proline Promass H 100 (Endress + Hauser Flow measurement). Verify with OEM before design.
Summary
Product identification
- Product: Proline Promass H 100
- Model: 8H1B
- Type: Coriolis flowmeter
- Headline: Chemically resistant single-tube flowmeter with an ultra-compact transmitter.
Field of application
Designed for applications requiring highest corrosion resistance with chemically aggressive fluids. Suitable for system integrators, skid builders, and equipment manufacturers where space is a premium.
Benefits
- Maximum safety for chemically aggressive fluids – corrosion-resistant wetted parts.
- Fewer process measuring points – multivariable measurement (flow, density, temperature).
- Space-saving installation – no in/outlet run needs.
- Space-saving transmitter – full functionality on the smallest footprint.
- Time-saving local operation without additional software and hardware – integrated web server.
- Integrated verification – Heartbeat Technology.
Operating limits
- Max. process pressure: PN 40, Class 300, 20K
- Medium temperature range:
- Tantalum: –50 to +150 °C (–58 to +302 °F)
- Zirconium: –50 to +205 °C (–58 to +401 °F)
- Ambient temperature range:
- Standard: –40 to +60 °C (–40 to +140 °F)
- Option: –50 to +60 °C (–58 to +140 °F)
Feed water
- Measuring principle: Coriolis
- Measured variables: Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration.
Product water
- Max. measurement error:
- Mass flow (liquid): ±0.1 %
- Volume flow (liquid): ±0.1 %
- Mass flow (gas, Tantalum only): ±0.5 %
- Density (liquid): ±0.0005 g/cm³
- Measuring range: 0 to 70 000 kg/h (0 to 2570 lb/min)
Mechanical / hydraulic
- Nominal diameter range: DN 8 to 50 (³⁄₈ to 2")
- Wetted materials:
- Measuring tube: Tantalum 2.5W; 702 (UNS R60702)
- Connection: Tantalum; 702 (UNS R60702)
- Sensor housing material: 1.4301 (304), corrosion resistant
- Transmitter housing material:
- Compact: AlSi10Mg, coated
- Compact/ultra-compact: 1.4301 (304)
- Degree of protection:
- Standard: IP66/67, type 4X enclosure
- Option: IP69
Electrical
- Outputs:
- 4–20 mA HART (active)
- Pulse/frequency/switch output (passive)
- Inputs: None
- Digital communication: HART, Modbus RS485, EtherNet/IP, PROFIBUS DP, PROFINET
- Power supply: DC 20 to 30 V
Approvals and Certifications
- Hazardous area approvals: ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC
- Product safety: CE, C-Tick, EAC marking
- Metrological approvals and certificates: Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR. Heartbeat Technology complies with the requirements for traceable verification according to ISO 9001:2008 – Section 7.6a (TÜV SÜD attestation).
- Pressure approvals and certificates: PED, CRN
- Material certificates: 3.1 material
Display/Operation
- 4-line backlit display available (no local operation)
- Configuration via web browser and operating tools possible