Quay lại Bel Pressure Vessels
BEL logo

Tóm tắt tài liệu kỹ thuật

16-S-300-1M-to-8M

Engineering summary from PDF text extraction for 16-S-300-1M-to-8M. Verify every value with the OEM datasheet.

Summary

Product identification

RO Pressure Vessel model: BEL 16-s(2x4)-300 psi. (also identified as 16s4-300).

Operating limits

  • Max. allowable working pressure: 300 psi (20.7 bar)
  • Permeate internal pressure: Not to exceed 125 psi (8.6 bar)
  • Operating temperature: Not to exceed 49 °C (120 °F)

Mechanical / hydraulic

  • Dimensions:
    • Drawing unit: mm (inches)
    • Body diameter: Ø422 [16.61 in]
    • Peak bell diameter: Ø495 [19.49 in]
    • Dimensions L, P, M can be varied according to exact membrane type.
    • Overall length shown in diagram (L): 1403.9 [15.9 in] (Note: The diagram has conflicting values for L, 1403.9 and 15.9 in, please refer to the official PDF for clarification.)
  • Ports:
    • Feed / Concentrate port: 4" victaulic
    • Permeate port: 3" victaulic
  • Components and Notes:
    • Screw hex head: DIN EN 24014 M8x100
    • Closing torque for item 19 (unspecified component in text): Not to exceed 2 Nm.
    • Saddles can be shimmed if required.
    • The vessel is supplied with two straps for external saddles.
    • Item 17 & 18 (unspecified components in text) should be located on the feed side for membrane shimming.
    • Item 13 (unspecified component in text) downstream only.
    • 3 supports are required for length code - 4 and over.

Warnings

  • Never pressurize a pressure vessel that was not loaded with membrane elements.
  • Wrong manifolding may cause excessive pressure on ports, which can lead to leaks.

Disclaimer: This summary is based on the extracted text and may not include all figures, footnotes, or the latest revisions from the original PDF. Contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

PDF datasheet

Nội dung tổng hợp từ tài liệu kỹ thuật công khai nhằm tra cứu và so sánh sơ bộ. Bản tóm tắt không thay thế bảng dữ liệu hiện hành được nhà sản xuất chứng nhận. Kiểm tra phiên bản và giới hạn thiết kế trước khi sử dụng.