Summary
Product identification
- 3M™ Liqui-Cel™ SP-4x28 Series Membrane Contactor
- Applications:
- Fluoroelastomer: General Purpose
- Perfluoroelastomer: Ultra Pure Water
Membrane Characteristics
- Cartridge Configuration: Extra-Flow with Center Baffle
- Membrane/Potting Material: Polyolefin / Polyethylene
Operating limits
- Liquid Flow Guidelines: 1.1-6.8 m³/hr (5-30 gpm)
- Liquid must flow on the shellside
- Maximum Shellside LIQUID Working Temperature/Pressure:
- 5-25°C, 4.1 barg (41-77°F, 60 psig)
- 50°C, 1.0 barg (122°F, 15 psig)
- If no vacuum is used, 1 barg (15 psig) can be added to pressures above.
- Maximum Applied Gas Pressure: 4.1 barg at 25°C (60 psig at 77°F)
- Note: Liquid pressure should always exceed gas pressure.
- See the official PDF for complete temperature/pressure limits for housings and membrane.
Mechanical / hydraulic
- All dimensions are nominal values for the Polypropylene housing with NPT connections. See full housing drawing on 3M.com/Liqui-Cel for additional details.
- Dimensions (nominal):
- 116 mm (4.6 in)
- 85 mm (3.3 in)
- Priming Volume (approximate):
Housing Material Shellside Lumenside Polypropylene 2.9 L (0.8 gal) 0.9 L (0.2 gal) 316L SS 2.9 L (0.8 gal) 0.7 L (0.2 gal) - Housing Characteristics:
- Material: Polypropylene, 316L SS (32 Ra finish)
- Flange Connections:
- Shellside (Wetted surface):
- 1 inch Sanitary
- ¾ inch NPT Female
- 1 inch George Fisher
- Rc ¾ per JIS B0203
- Lumenside (Gas/Vacuum):
- 1 inch 90° Sanitary
- ¾ inch 90° NPT Female
- Rc ¾ per JIS B0203
- 1 inch Sanitary
- Shellside (Wetted surface):
- Seal Material Options: Fluoroelastomer, Perfluoroelastomer
- Weight (approximate):
Housing Material Dry Water-filled Polypropylene 4 kg (9 lbs) 7 kg (16 lbs) 316L SS 7 kg (16 lbs) 10 kg (22 lbs)
Regulatory
- Complies with the limits as set by RoHS Directive 2011/65/EU Annex II; recasting 2002/95/EC.
- Constructed of FDA CFR title 21 compliant materials for wetted parts only at ambient temperatures.