Tóm tắt tài liệu kỹ thuật

3M Liqui-Cel membrane contactor power plant thailand

Engineering summary from PDF text extraction for 3M Liqui-Cel membrane contactor power plant thailand. Verify every value with the OEM datasheet.

Summary

Product Identification

This document describes the application of 3M™ Liqui-Cel™ Membrane Contactors in a power plant in Thailand to remove CO₂ from water. The system utilizes one 14-inch membrane contactor.

Operating Limits

  • Raw Water Feed Inlet:
    • CI₂: 2 ppm
    • Turbidity: 0.8-6 NTU
    • Pressure: 1.6 bar min.

Feed Water

The membrane contactor is used downstream of a double pass Reverse Osmosis (RO) system. The pH of the water entering the membrane contactor is typically below 6.

Raw Water Influent Analysis (Clarified Surface Water)

  • Turbidity: 0.8-5 NTU
  • pH: 6.5-8
  • Conductivity: 400 µS-cm
  • TDS: 280 mg/l
  • M-Alkalinity: 100 mg/l as CaCO₃
  • Total Hardness: 120 mg/l as CaCO₃
  • Calcium Hardness: 75 mg/l as CaCO₃
  • Chloride: 45 mg/l as Cl⁻
  • Iron: 0.01 mg/l as SO₄
  • Sulfate: 26 mg/l as SO₄
  • Phosphate: 0.03 mg/l as PO₄
  • Silica: 15 mg/l as SiO₂

RO Feed Quality (after 150 micron pre-filter and Microfiltration)

  • Turbidity: <0.5 NTU
  • SDI: <3

Product Water

The overall system (RO-LMC-EDI) produces DI water with:

  • Resistivity: >16.0 MΩ-cm
  • Silica: <0.02 mg/l as SiO₂

Mechanical / Hydraulic

  • Contactor Size: One 14-inch membrane contactor
  • Membrane Type: Hydrophobic polypropylene membrane
  • Membrane Pore Size: 0.03 µm
  • Operating Mode: Combination mode using vacuum and air sweep

General Application

3M™ Liqui-Cel™ Membrane Contactors remove dissolved CO₂ from water, particularly benefiting Electrodeionization (EDI) systems by reducing the ionic load and improving water quality. The contactors prevent air-to-water contamination by using a hydrophobic membrane with 0.03 µm pores, which is a key advantage over forced draft deaerators. This mechanical removal of CO₂ reduces the need for chemicals and pH adjustment.


Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the OEM PDF. For contractual data, always refer to the specific OEM PDF revision used on the project.