Tóm tắt tài liệu kỹ thuật
TwinFlo SXT
Engineering summary from PDF text extraction for TwinFlo SXT. Verify every value with the OEM datasheet.
Summary
Product identification
- Product Name: TwinFloSXT
- Type: Residential Twin Tank Control Valve
- Part Number: 42804 Rev B
Features
- Uses 100% capacity of the tank in service before switching to the second tank, saving salt and water.
- Rinses away hardness reversion and stagnant water before the stand-by tank comes on line.
- Regenerates with soft water, keeping the system clean for optimum operating efficiency and minimum maintenance.
- Regenerates immediately when needed for continuous soft water 24 hours a day.
- Valve delivers continuous soft water.
- Meter-initiated regeneration.
- Super capacitor for keeping time during a power outage.
Options
- Fiber-reinforced polymer or stainless steel bypass valves.
Valve Specifications
Valve Material
Fiber-reinforced polymer
Inlet/Outlet
3/4", 1", 1-1/4"
Cycles
5
Flow Rates (50 psi Inlet) - Valve Alone
- Continuous (15 psi drop): 15 GPM
- Peak (25 psi drop): 19 GPM
- Cv (flow at 1 psi drop): 3.8
- Max. backwash (25 psi drop): 4 GPM
Regeneration
- Type: Downflow/Upflow or Downflow only
- Adjustable cycles: Yes
- Time available per cycle: 0-199 minutes
Meter Information
- Accuracy: .75 - 15 GPM +/- 5%
- Capacity range (gal.): 1 - 999,900
Dimensions
- Distributor pilot: 1.05" O.D.
- Drain line: 1/2" NPTF
- Injector brine system: 1610
- Brine line: 3/8"
- Mounting base: 2-1/2" - 8 NPSM
- Height from top of tank: 7.5"
Typical Applications
- Water softener tank diameter: 6" - 10"
Operating Limits
Pressure
- Hydrostatic: 300 psi
- Working: 20 - 125 psi
Temperature
- 34° - 110° F
Electrical
- Rating: 24 v - 50Hz, 60 Hz
- Max. VA: 8.9
Mechanical / Hydraulic
- Estimated shipping weight (Metered valve): 15 lbs.
Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.