Summary

Product identification

Vitec® 5100 is a liquid antiscalant/dispersant.

Performance

  • Powerful inhibitor against a variety of scales, including:
    • CaCO₃ (CCPP ≤ 900, LSI ≤ 2.8)
    • CaSO₄ (3.0 x Ksp)
    • BaSO₄ (10⁵ x Ksp)
    • SrSO₄ (20 x Ksp)
    • CaF₂ (1000 x Ksp)
    • SiO₂ (120 ppm)
  • Highly effective at low dose rates in a wide range of feedwater types and pH ranges.
  • Compatible with polyelectrolytes.
  • Provides both scale and inorganic fouling control.
  • Compatible with all membrane types.
  • Formulated to inhibit scale and disperse colloidal particles in cellulose acetate and polyamide membrane separation systems.
  • Certified by NSF International under ANSI/NSF Standard 60 for use in systems producing potable water.
  • Compatible with Avista’s RoQuest® organic coagulants.

Application

  • Inject upstream of the membrane system and, where possible, upstream of cartridge filters.

Dosing Guidelines

  • Typical dosage range: 2 to 5 ppm.
  • A site-specific dose can be determined using the Avista Advisor computer program.
  • Contact Avista customer service for customized dosing instructions.

Dilution

  • Product is formulated to be injected neat.
  • If dilution is required, use demineralized or RO permeate water. Softened water may be substituted if the above are unavailable.
  • Dilution should not result in a solution strength of less than 10% to protect the internal bacteriostat.

Specifications

  • Appearance: Clear, yellow liquid
  • pH (2% solution): 5.0 – 6.5
  • Specific Gravity @ 20°C: 1.10 ± 0.05

Packaging and Storage

  • Standard regional pack sizes:
    • Pails: 45 lbs (23 kgs)
    • Drums: 500 lbs (230 kgs)
    • IBC’s (totes): 2500 lbs (1100 kgs)
  • Custom packaging is available.
  • Information on drumless or bulk tanker delivery is available on request.

NSF Certification

  • Certified by NSF International to NSF/ANSI 60 for use as a drinking water treatment chemical in reverse osmosis systems at a maximum level of 13 mg/l.