RO recovery, concentrate, water and salt balance anomalies
Use this when ro recovery, concentrate, water and salt balance anomalies is observed but the cause remains unclear. The diagnostic checks measurement and sampling, operating changes, issue location, and key evidence before suggesting likely causes and the next useful check.
First time here? Start with this
You do not need every data point before you begin
The system asks one discriminating question at a time and updates the candidate causes on the right. Answer from current facts; choose unknown or defer a question when the evidence is not available.
- 1
Confirm the issue
Check whether the symptom is reproducible and whether the measurement or observation is reliable.
- 2
Narrow the causes
Continue through operating changes, issue location, and available inspection results.
- 3
Read the live result
Candidate causes, support, counter-evidence, conflicts, and next actions update as you answer.
This tool analyzes information you already have. It does not insert a safety screen or use safety status to stop the diagnosis. If an alarm, leak, or injury is happening now, follow the site emergency procedure directly.
Automatic troubleshooting · Selections are not uploaded
Only one question is shown at a time. Answer from current facts or defer an unknown item. Possible causes and next checks update on the right as you answer.
- 1Data validity
- 2Operating changes
- 3Issue location
- 4Further confirmation
Question progress
0/15
- Answered
- 0
- To confirm
- 15
- Clues found
- 0
Load a test scenario
Next question
Phase 1 · Data validity
Have feed, permeate, and concentrate flows been independently verified or calibrated?
The system asks the question most useful for separating possible causes. Unknown or deferred items are not treated as the opposite conclusion.
I have more test or inspection resultsOptionalAdd laboratory analysis, normalized calculations, or checks completed by trained personnel when available. These fields are optional.
View rule sources (10)Standards, regulations, OEM material, and peer-reviewed literature used to audit the diagnostic logic. You do not need to read them before starting.
Each rule cites material directly relevant to its judgment. Current OEM and site procedures remain controlling.
- A-standard · ASTM International · 2023ASTM D4194-23 — Standard Test Methods for Operating Characteristics of Reverse Osmosis and Nanofiltration Devices
- A-standard · ASTM International · 2023ASTM D4195-23 — Standard Guide for Water Analysis for Reverse Osmosis and Nanofiltration Application
- A-standard · ASTM International · 2023ASTM D4472-23 — Standard Guide for Recordkeeping for Reverse Osmosis and Nanofiltration Systems
- A-standard · ASTM International · 2019ASTM D3739-19 — Standard Practice for Calculation and Adjustment of the Langelier Saturation Index for Reverse Osmosis
- A-standard · ASTM International · 2023ASTM D4582-23 — Standard Practice for Calculation and Adjustment of the Stiff and Davis Stability Index for Reverse Osmosis
- A-standard · ASTM International · 2026ASTM D4692-01(2026) — Sulfate Scaling Salts for RO/NF
- A-oem-current · DuPont Water Solutions · 2026FilmTec Reverse Osmosis/Nanofiltration Membranes Technical Manual, Rev. 19
- A-oem-current · DuPont Water Solutions · 2026FilmTec Membrane Additional Information Tech Fact, Form 45-D04931-en
- B-independent-oem · LG Water Solutions · 2025Technical Service Bulletin 111 — Data Logging and Performance Normalization
- C-peer-reviewed-review · Science of the Total Environment · 2017A review of reverse osmosis membrane fouling and control strategies