ملخص ورقة البيانات
PT series
PDF datasheet mirror for PT series (SUEZ Ultrafiltration). Verify with OEM before design.
Summary
Product identification
The PT series consists of industrial ultrafiltration elements utilizing a polyethersulfone (PES) membrane with a 5,000-molecular weight cut-off (MWCO).
- Membrane: P-Series, Polyethersulfone
| Model | Spacer mil (mm) | Active area ft² (m²) | Outer wrap | Part number |
|---|---|---|---|---|
| PT8040C50 | 50 (1.27) | 264 (24.5) | Cage | 1240574 |
| PT8040F30 | 30 (0.76) | 340 (31.6) | Fiberglass | 1229772 |
Operating limits
- Typical Operating Flux: 5 – 20 GFD (8 – 34 LMH)
- Maximum Operating Pressure: 200 psi (1,379 kPa)
- Maximum Temperature:
- Continuous Operation: 122°F (50°C)
- Clean-In-Place (CIP): 122°C (50°C)
- pH range:
- Continuous Operation: 2.0-10.0
- Clean-In-Place (CIP): 1.0-11.5
- Maximum Pressure Drop:
- Over an element: 15 psi (103 kPa)
- Per housing: 60 psi (414 kPa)
- Chlorine Tolerance: 5,000 ppm days
Mechanical / hydraulic
| Model | Dimensions, inches (cm) A | Dimensions, inches (cm) B¹ | Dimensions, inches (cm) C² | Boxed Weight lbs (kg) |
|---|---|---|---|---|
| PT8040 | 40.0 (101.6) | 1.125 (2.86) | 7.9 (20.1) | 29 (13.2) |
¹ Internal diameters unless specified OD (outside diameter). ² The element diameter (dimension C) is designed for optimum performance in GE Water & Process Technologies pressure vessels. Other pressure vessel dimensions and tolerances may result in excessive bypass and loss of capacity.
Disclaimer: This summary is based on the provided text extract. It may not include all figures, footnotes, or the latest revisions from the official OEM PDF datasheet. Contractual data must always match the specific OEM PDF revision used on the project.
Official datasheet (PDF)
أُعد المحتوى من مراجع تقنية عامة للبحث والمقارنة الأولية. لا يغني الملخص عن ورقة بيانات حالية معتمدة من الشركة المصنعة. تحقق من الإصدارات وحدود التصميم قبل الاستخدام.