Summary

Product identification

The PT series consists of industrial ultrafiltration elements utilizing a polyethersulfone (PES) membrane with a 5,000-molecular weight cut-off (MWCO).

  • Membrane: P-Series, Polyethersulfone
ModelSpacer mil (mm)Active area ft² (m²)Outer wrapPart number
PT8040C5050 (1.27)264 (24.5)Cage1240574
PT8040F3030 (0.76)340 (31.6)Fiberglass1229772

Operating limits

  • Typical Operating Flux: 5 – 20 GFD (8 – 34 LMH)
  • Maximum Operating Pressure: 200 psi (1,379 kPa)
  • Maximum Temperature:
    • Continuous Operation: 122°F (50°C)
    • Clean-In-Place (CIP): 122°C (50°C)
  • pH range:
    • Continuous Operation: 2.0-10.0
    • Clean-In-Place (CIP): 1.0-11.5
  • Maximum Pressure Drop:
    • Over an element: 15 psi (103 kPa)
    • Per housing: 60 psi (414 kPa)
  • Chlorine Tolerance: 5,000 ppm days

Mechanical / hydraulic

ModelDimensions, inches (cm) ADimensions, inches (cm) B¹Dimensions, inches (cm) C²Boxed Weight lbs (kg)
PT804040.0 (101.6)1.125 (2.86)7.9 (20.1)29 (13.2)

¹ Internal diameters unless specified OD (outside diameter). ² The element diameter (dimension C) is designed for optimum performance in GE Water & Process Technologies pressure vessels. Other pressure vessel dimensions and tolerances may result in excessive bypass and loss of capacity.