Datasheet summary
Memtrex MP CMMP capsules
Engineering summary from PDF text extraction for Memtrex MP CMMP capsules. Verify every value with the OEM datasheet.
Summary
Product identification
Memtrex MP Capsules (CMMP) are capsule filters utilizing unique polyethersulfone membranes.
Available absolute micron ratings are:
- 0.1 µm
- 0.2 µm
- 0.45 µm
- 0.65 µm
- 1.0 µm (for ordering)
Typical Applications Specifically designed for filtration of process fluids in the beverage, pharmaceutical, and electronics industries, including:
- Acids, bases, and oxidants
- Serums and tissue culture media
- Pharmaceutical intermediates
- Fine inks and dyes
- Point-of-use for process water
Features and Benefits
- High throughput and precise retention characteristics
- Broad chemical compatibility — ideal for filtration of acids, bases, and solvents
- Individually integrity tested during manufacturing
- Rinsed with DI water during manufacturing for improved cleanliness and rinse-up times
- Low protein binding membrane suitable for biopharmaceutical processes
Materials of Construction
- Filtration Media: Hydrophilic Polyethersulfone Membrane
- Membrane Support Layers: Polypropylene Microfiber
- Structural Components: Polypropylene
Mechanical / Hydraulic
Dimensions
- Diameter: 3.5” (9 cm)
- Capsule Size / Effective Filtration Area / Length (varies with connection style):
- Small: 0.8 ft² (748 cm²), 3.5 – 5.0” (9 – 13 cm)
- Medium: 3.0 ft² (2806 cm²), 7.6 – 9.1” (19 – 23 cm)
- Large: 5.9 ft² (5500 cm²), 11.5 – 13.0” (29 – 33 cm)
Connection Options (for ordering)
- ¼” – ½” (6.3 – 12.7 mm) hose barb
- 3/8” (9.5 mm) hose barb
- ¼” (6.3 mm) NPT male
- ½” (12.7 mm) NPT male
- 1.5” (38.1 mm) sanitary flange
Operating limits
- Max. Operational Pressure:
- 80 psi (5.5 bar) at 70ºF (21ºC) in liquid
- 55 psi (3.8 bar) at 70ºF (21ºC) in gas
- Max. Differential Pressure: 60 psi (4.1 bar) at 70ºF (21ºC)
- Max. Operating Temperature: 110ºF (43ºC) at ≤30 psid (2.1 bar) operating pressure
Integrity Testing
Integrity testing is performed by air diffusion through water-saturated membrane.
- 0.1 µm: Test Pressure 50 psi (3.4 bar), Specification ≤5.6 cc/min per ft² of EFA
- 0.2 µm: Test Pressure 30 psi (2.1 bar), Specification ≤2.4 cc/min per ft² of EFA
- 0.45 µm: Test Pressure 20 psi (1.4 bar), Specification ≤2.0 cc/min per ft² of EFA
- 0.65 µm: Test Pressure 13 psi (0.9 bar), Specification ≤1.5 cc/min per ft² of EFA
Additional Information
- Sanitization: Memtrex MP capsule filters may be sanitized with a variety of commonly used chemical agents. The capsules may be repeatedly autoclaved at 257°F (125°C) for 30 minutes up to 5 cycles.
- Compliance: Veolia certifies that materials meet U.S. FDA requirements for food contact under applicable regulations in 21 CFR. Memtrex MP filters meet the test criteria for USP class VI-121°C Plastics.
- Flow performance data for small, medium, and large capsules in clean water is available in the official PDF document.
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions. Contractual data must match the OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.