Datasheet summary
Hytrex RX
Engineering summary from PDF text extraction for Hytrex RX. Verify every value with the OEM datasheet.
Summary
Product identification
The Hytrex RX is a melt blown depth filter specifically engineered for oil and gas applications.
Features and Benefits
- Engineered specifically for oil and gas applications
- Combines efficiency, long life, and strength
- Continuous manufacturing process assures consistent and reliable performance
- Wide chemical compatibility
- Pure polypropylene construction
- True depth media traps particles throughout the filter
Operating limits
- Maximum pressure drop: 35 psid (2.4 bar) @ 77°F (25°C)
- Recommended change-out pressure drop: 20 psid (1.4 bar) @ 77°F (25°C)
Mechanical / hydraulic
- Ratings (nominal): 1, 3, 5, 10, 20, 30, 50, 75 microns
- Inner Diameter (nominal): 1 in (2.5 cm)
- Outer Diameter: 2.75 in (7.0 cm)
- Lengths: 36 in (91 cm)
- Longer lengths up to 70 in may be available upon request.
- Materials of Construction:
- Filter Media: Polypropylene
- Adapters: Polypropylene
- Elastomer: EPDM, Silicone, Santoprene¹ (flat gasket only)
Performance information
The efficiency of nominal filters varies by application. Nominal-rated filters have a wider distribution of pore sizes and rejected particle sizes. The nominal rating is primarily used for comparing efficiencies across filter families and between manufacturers. Efficiency depends on particle shape, size, composition, application, and testing protocol.
Clean water flow rate information based on a 10 inch length filter is provided in a graph in the official PDF. See the official PDF for exact tabulated values.
Quality and Certifications
Hytrex RX filters are manufactured under a quality management system certified to meet ISO 9001 standards. Each filter is assigned a lot code for traceability of data and materials.
Certifications:
- U.S. FDA 21CFR 177 food contact requirements
- U.S. FDA 21CFR 174.5 food contact requirements
- NSF 61 criteria
- ISO 9001 criteria
Ordering information
The product can be ordered by replacing numbers with desired values in the format RX [Micron Rating]-[Cartridge Length]-[End #1 Adapter][End #2 Adapter].
- Example: RX 05-336-XK
- Micron Rating (nominal):
- 01 = 1 µm
- 03 = 3 µm
- 05 = 5 µm
- 10 = 10 µm
- 20 = 20 µm
- 30 = 30 µm
- 50 = 50 µm
- 75 = 75 µm
- Cartridge Length:
- 336 = 36 in (91 cm)
- Longer lengths up to 70 in may be available upon request.
- End #1 Adapter:
- X = Standard Plain End (no gasket)
- End #2 Adapter:
- K = Self Seal Spring
- Use "-B" for bulk packaging.