Back to SUEZ Filtration
SUELogo pending

Datasheet summary

1 Round HX Housings

Engineering summary from PDF text extraction for 1 Round HX Housings. Verify every value with the OEM datasheet.

Summary

Product identification

The 1-Round HX Cartridge Filter Housings are stainless steel, single-round cartridge filter housings designed for a variety of applications. They are compatible with various cartridge styles. The product line includes HX and HX-222 models.

Operating limits

  • Liquid Pressure Rating: 250 psig @ 150°F (17.2 bar @ 66°C)

Mechanical / hydraulic

  • Housing Material: 316 Stainless Steel
  • Inlet/Outlet Connections: 3/4–inch (19.1 mm) FNPT
  • Upstream Drain Port: 1/4–inch (6.35 mm) FNPT
  • Post-Filter Gauge Port: 1/4–inch (6.35 mm) FNPT (plugged)
  • O-Ring Material:
    • Buna-N (standard)
    • EPDM, Silicone, Viton, and Teflon encapsulated Viton (optional)
  • Cartridge Lengths Supported:
    • 9.25–10.0-inch (23.5–25.4 cm)
    • 19.25–20.0-inch (48.9–50.8 cm)
  • Cartridge Outer Diameter (OD) Compatibility: 2.25- to 3.13-inch (5.7 to 8.0 cm)
  • Finish: Satin Finish
  • Construction: TIG welding performed at Veolia factories for quality control.

Features

  • Stainless Steel Construction: Provides corrosion resistance and strength, capable of handling frequent on/off cycling or harsh chemical environments.
  • V-Band Clamp Closure: Allows for quick and easy cartridge filter replacement, reducing labor costs and downtime.
  • Cartridge Sealing Mechanism:
    • HX models use a drawbar and seal cup for a worry-free cartridge seal.
    • HX-222 models use a special head to seal the 222 O-ring adapter.
    • Both designs allow inspection of all seals before the sump is secured.
  • Cartridge Compatibility: Designed for use with Hytrex, Purtrex, Selex, and Memtrex brand cartridges, and most other brands of cartridge filters within the specified OD range.

Housing Specifications

ModelFlow Rate* gpm (Lpm)Length “A” (Overall housing height) Inch (cm)Length “B” (Height required to remove cartridges) Inch (cm)Empty weight lb (kg)
HX0110-.75T-316-A< 5 (19)15.3 (39)27 (69)8 (4)
HX0120-.75T-316-A< 10 (38)25.3 (64)47 (119)11 (5)
HX0110-.75T-316-A-222< 5 (19)15.3 (39)27 (69)8 (4)
HX0120-.75T-316-A-222< 10 (38)25.3 (64)47 (119)11 (5)

*Flow rate is dependent upon cartridge filter selection, fluid properties, and maximum acceptable pressure drop. Note: Draw bar and bottom seal cup are not included with HX-222 models.

Optional Accessories

  • Pressure Gauge, Bottom Mount, 316SS, ¼ “ MNPT, 0-300 psig (20.7 bar)
  • T-Handle for V-Band Clamp
  • HX01 EPDM Housing Seal Kit
  • HX01 Viton Housing Seal Kit
  • HX01 Silicone Housing Seal Kit