Back to Eaton Filtration
Eaton logo

Datasheet summary

Sideline

Engineering summary from PDF text extraction for Sideline. Verify every value with the OEM datasheet.

Summary

Product identification

SIDELINE™ Filter Housings are mid-priced, investment-cast filter housings designed for most applications. They are suitable for heavy-duty industrial applications.

Key features:

  • Solid, investment-cast filter construction.
  • Standard eye-bolt closure.
  • Standard 2˝ or 3˝ ANSI flanged connections are available, with NPT options.
  • Accommodates filter bags sizes 01, 02, 03, and 04.
  • Type 316 stainless steel construction for superior corrosion resistance and consistent performance. (SS = Austenitic Stainless Steel SS 316 and CF8M or better).
  • Smooth, bead-blasted finish and minimum 2-weld design for easy cleaning of the interior.
  • Side inlet with evacuation cover.
  • Cover opening direction can be changed.
  • Compression bag hold down.
  • Integral cover handle for ergonomic and easy opening.
  • Less messy bag changing, reducing spillage.
  • Can accommodate walls, posts or other obstructions.
  • Exclusive Five Year Warranty and ASME code UM stamp.

Product Code Configuration

Product codes follow a pattern (example: D-MBF-0402-AC10-050D):

  • D: D-DUOLINE
  • MBF: VMBF-MAXILINE, M-MODULINE, MBF-MAXILINE, TBF-TOPLINE, SBF-SIDELINE, PBF-POLYLINE, FBF-FLOWLINE, EBF-ECOLINE
  • 04: No. of bags (01, 02, 04, 08, 12, 16, 20, 24, Up to 140-14")
  • 02: Bag Size (01-short 7", 02-long 7", 03-short 4", 04-long 4")
  • AC: Material (AB-SS316, CS-Carbon Steel, PO-Polypropylene, PF-PVDF)
  • 10: Pressure rating (10-150 psi, 21-300 psi)
  • 050: Connection Size (050-1/2", 010-1", 012-1¼", 015-1½", 020-2")
  • D: Connection Type (A-ANSI Flange, N-NPT Female Thread)

Operating limits

  • Max. Allowable Pressure:
    • 150 psi for many models.
    • 300 psi for SBF-0103-AB21-015N and SBF-0104-AB21-015N models.
  • Max. Allowable Temperature:
    • 225 °F for SBF-0103-AB21-015N and SBF-0104-AB21-015N models.
    • 400 °F for other SBF- models (depending on seal material).

Mechanical / hydraulic

SIDELINE™ filter housings are available in various configurations, including single-bag and multi-bag units.

General Parameters (SIDELINE models)

ParameterValue
No. Of Bags1, 2, or 1+1
Bag Size1, 2, 3, 4
MaterialSS (Type 316 stainless steel and CF8M or better)
Max. Allowable Pressure150 psi or 300 psi
Max. Allowable Temperature225 °F or 400 °F
Inlet Outlet Connection1½", 2", 3"
Connection TypeFlanged, NPT
Vent¼"

Specific SIDELINE Models (SBF-)

Type*No. Of BagsBag SizeMax. FlowMaterialMax. Allowable Pressure (PSI)Max. Allowable Temperature (ºF)Housing Volume (GAL)Housing Weight (LBS)Inlet Outlet ConnectionConnection TypeVent
SBF-0101-AB10-020A1190SS1504004.75842"Flanged¼"
SBF-0101-AB10-030A1190SS1504004.75843"Flanged¼"
SBF-0102-AB10-020A12180SS1504008.51022"Flanged¼"
SBF-0102-AB10-030A12180SS1504008.51023"Flanged¼"
SBF-0103-AB21-015N1325SS3002250.5261½"NPT¼"
SBF-0104-AB21-015N1450SS3002250.7291½"NPT¼"

Multi-bag SIDELINE Models

SERIESNo. Of BagsBag SizeMax. FlowMaterialMax. Allowable Pressure (PSI)Max. Allowable Temperature (ºF)Housing Volume (GAL)Housing Weight (LBS)Inlet Outlet ConnectionConnection TypeVent
SIDELINE22180SS150250163002"Flanged¼"
SIDELINE22180SS150250173303"Flanged¼"
SIDELINE1+12360SS150250162302"Flanged¼"
SIDLINE1+12360SS150250173003"Flanged¼"

Note: For the "Max. Flow" column in the tables, the unit is not explicitly stated in the table header or footnote for these specific values. The general legend mentions "Max. Flow 2 GPM" but this seems to be a generic placeholder not applied to the specific model values. See the official PDF for exact tabulated values.

Disclaimer: This summary is based on the provided text extract and may not include all figures, footnotes, or the latest revisions. Contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

Lenntech datasheet mirror

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.