Summary

Product identification

BECO MEMBRAN PSplus filter cartridges are designed for the final filtration of various beverages. They are available with nominal separation rates for different applications:

  • 0.2 µm
  • 0.45 µm
  • 0.65 µm
  • 0.8 µm

Key advantages include:

  • Safe separation of microorganisms, based on chosen pore width.
  • Materials enable regular cleaning and sterilization for economic operation.
  • Easily wettable, simplifying integrity testing.
  • Preservation of organoleptic product attributes due to inert filter medium.
  • Wide chemical compatibility.

Operating limits

  • Maximum operating temperature: 80 °C (176 °F)
  • Maximum differential pressure:
    • 5.0 bar (72.5 psid) at 20 °C (68 °F)
    • 2.0 bar (29 psid) at 80 °C (176 °F)
    • 0.3 bar (4 psid) at 121 °C (250 °F)
  • Sterilization with hot water: max. 90 °C (194 °F)
  • Sterilization with steam: max. 121 °C (250 °F), 100 cycles at 110 °C (230 °F) for 30 minutes

Feed water

For hot water sterilization and flushing/regeneration, water should be softened and filtered (approx. 1 µm) to prevent lime precipitation and premature clogging.

Mechanical / hydraulic

  • Diameter: 70 mm (2.75 in)
  • Nominal Filter Area:
    • 10"/250 mm: 0.7 m² (7.5 ft²)
    • 20"/500 mm: 1.4 m² (15.1 ft²)
    • 30"/750 mm: 2.1 m² (22.6 ft²)
    • 40"/1,000 mm: 2.8 m² (30.1 ft²)

Filter Cartridge Design and Materials

The cartridges are constructed with:

  • Filter membrane: Polyethersulfone
  • Support fleeces: Polyester
  • Internal and external support body: Polypropylene
  • End caps/adapters: Nylon, adapter with stainless steel ring
  • O-rings: Silicone (standard)

Plastic components comply with Directive 2002/72/EC and amendments. All materials meet FDA requirements per 21 CFR § 177.

Titre Reduction

Guide values for 75 cm (30") element with water at 20 °C (68 °F).

Pore sizeTest organismTitre reduction /cm²
PES02Brevundimonas diminuta> 10⁷
PES04Serratia marcescens> 10⁷
PES06Saccharomyces cerevisiae> 10⁷
PES08Saccharomyces cerevisiae> 10⁶

Integrity Test

For 10" filter cartridge.

Filter cartridge typesTest pressure [bar/psig]Max. diffusion rate per 25 cm element
PES022.4/35</= 20 ml/min
PES041.7/25</= 20 ml/min
PES061.0/14.5</= 20 ml/min
PES080.6/9</= 20 ml/min

Sterilization

  • Steam sterilization:
    • With steam at 110 °C (230 °F) / 0.5 bar (7 psig).
    • Duration: Minimum 20 minutes after steam emerges from all openings of the filtration system.
  • Hot water sterilization:
    • Using water up to 90 °C (194 °F) maximum.
    • Duration: At least 30 minutes once 85 °C (185 °F) is reached from all openings of the filtration system.
    • Water should be softened and filtered (approx. 1 µm) to avoid lime precipitation.

Flushing/Regeneration

Cartridges should be rinsed daily after use, in the direction of product flow, using filtered (approx. 1 µm), softened water under counterpressure. This helps remove deposited, water-soluble haze substances (e.g., polysaccharides, proteins, tannins, tartaric acid crystals). Rinsing with hot water (80 °C/176 °F) can remove stubborn residues if applied in time; the hot water may remain in the filter overnight.

Ordering Information

Example ordering code: PES 02 7 1 S corresponds to a BECO MEMBRAN PSplus filter cartridge; 0.2 µm retention rate; Code 7 adapter; 10" length; Silicone gasket.

Filter cartridge typeRetention rateAdapterNom. lengthGasket
PES02 = 0.20 µm0 = Code 01 = 10"/25 cmS = silicone
04 = 0.45 µm2 = Code 2*2 = 20"/50 cm
06 = 0.65 µm7 = Code 73 = 30"/75 cm
08 = 0.80 µm4 = 40"/100 cm

*Code 2 can be used instead of Code 5 (details for Code 5 not provided).

Adapter Codes

  • Code 0: 2-222 O-ring without centre point
  • Code 2: 2-222 O-ring 3-way bayonet adapter with centring point
  • Code 7: 2-226 O-ring 2-way bayonet adapter with centring point

Safety

When used as directed and handled correctly, there are no known unfavorable effects. The product does not require safety-relevant information. Storage, handling, and transport do not present environmental or health risks.

Disposal

BECO MEMBRAN PSplus filter cartridges should be treated as industrial waste. Local and official regulations related to the filtered product must be followed.

Storage

Store filter cartridges in their original packaging, in a dry and odour-free place. Avoid storing near evaporating chemicals, oils, or fuels. Cartridges should be used within 2 years of delivery.


Disclaimer: This summary is based on the provided text extract. It may not include all figures, footnotes, or the latest revisions present in the official PDF datasheet. For contractual data, please refer to the specific OEM PDF revision used for your project.