Datasheet summary
Beco Membran H
Engineering summary from PDF text extraction for Beco Membran H. Verify every value with the OEM datasheet.
Summary
Product identification
The BECO MEMBRAN H filter cartridge (0.2 µm) is designed for sterile gas filtration applications, removing contamination down to 0.01 µm in gases.
Operating limits
- Continuous operating temperature: Approximately 80 °C (for up to one year)
- Steam resistance: Long-term at 145 °C
- Sterilization cycles:
- Up to 150 times in filtration direction
- Up to 50 times against filtration direction
- At 145 °C for 30 minutes with steam
Mechanical / hydraulic
- Materials:
- Hydrophobic PTFE membrane
- Internal and exterior support body and end caps made from polypropylene
- Dual O-ring made from silicone
- Pore size: 0.2 µm
- Nominal cartridge length and filter surface area:
- 25 cm/10": 0.7 m²
- 50 cm/20": 1.4 m²
- 75 cm/30": 2.1 m²
- Differential pressure:
- Max. differential pressure:
- 7.0 bar at 25 °C
- 1.7 bar at 80 °C
- 0.35 bar at 145 °C
- Max. counter pressure: 5.2 bar at 25 °C, periodic
- Max. differential pressure:
- Adapter: Code 7 (single open end with double O-ring and double bayonet, 2-226 with spear)
- Throughput (Code 7 at 3.5 bar inlet pressure):
- 10"/25 cm: 250 Nm³/h
- 20"/50 cm: 500 Nm³/h
- 30"/75 cm: 700 Nm³/h
- A graph showing flow rate in Nm³ per hour based on a 10" element at various inlet pressures (0.0, 1.0, 2.1, 3.5, 5.0 bar) is available in the PDF.
Performance / Validation
- Contamination removal: Down to 0.01 µm in gases.
- Integrity: Ensured even after several steaming cycles or continuous steaming over 165 hours.
- Integrity test (per 10" cartridge element at 23 °C):
- Nitrogen diffusion: ≤ 15 ml/min at 0.7 bar with 60 % isopropanol.
- Bubble point pressure: ≥ 895 mbar with 60 % isopropanol.
- Virus aerosol retention: A 10" filter cartridge fully retains 10⁸ – 10¹⁰ ΦX-174 phages even after 50 application cycles (SIP) at 145 °C and a flow rate of 85 Nm³/h.
- Bacterial penetration: No penetration of Pseudomonas diminuta occurs for at least 21 days when subjected to 10⁷ organisms/cm².
Safety / Disposal / Storage
- Safety: No known unfavorable effects, safety-relevant information is not required. No known risks to humans or the environment during storage, handling, and transport.
- Disposal: Treat as industrial waste. Follow local and official regulations.
- Storage: Store in original packaging, in a dry and odor-free place. Do not store near evaporating chemicals, oils, or fuels. Use within 2 years after delivery.
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the OEM PDF datasheet. For contractual data, please refer to the specific OEM PDF revision used on your project.