العودة إلى Thermax
Thermax logo

ملخص ورقة البيانات

Thermax Tulsion T 52 Na BC UPS

PDF datasheet mirror for Thermax Tulsion T 52 Na BC UPS (Thermax). Verify with OEM before design.

Summary

Product identification

  • Product Name: TULSION® T-52 Na BC N
  • Product Description: PREMIUM STRONG ACID CATION NUCLEAR GRADE RESIN
  • Resin Type: Gel type, produced as moist spherical beads, containing Sulphonic acid as the functional group.
  • Features: Excellent resistance to oxidizing agents with high operating capacity. Most suitable for water treatment and suited for use in a wide pH range and elevated temperature conditions. NSF grade resin, conditioned to achieve low VOCs.

Typical Characteristics

  • Type: Strong acid cation exchange resin
  • Matrix structure: Crosslinked copolymer
  • Functional group: Sulphonic
  • Physical form: Black colored moist beads
  • Ionic form: Sodium
  • Screen size USS (wet): 16 to 50
  • Particle size (min. 95%): 0.3 to 1.2 mm
  • Total exchange capacity (min.): 2.2 meq / ml
  • Moisture %: 43 ± 3%
  • Backwash settled density: 830 to 860 g/lit
  • Temperature stability (max): 140 °C
  • pH range: 0 to 14
  • Solubility: Insoluble in all common solvents.

Typical Operating Conditions

  • Maximum operating temperature: 140°C (in Na form)
  • Resin bed depth (min): 600 mm
  • Maximum service flow: 120 m³/hr/m³
  • Backwash expansion space: 40 to 75%
  • Backwash flow: 9 to 20 m³/hr/m³
  • Regenerant: HCl/ H₂SO₄ for H form; NaCl for Na form
  • Regeneration level: 30 to 160 g HCl/l ; 40 to 250g/l H₂SO₄ ; 60 to 160 NaCl g/l
  • Regenerant concentration: 3 to 4% HCl; 1.5 to 5% H₂SO₄; 10 to 15% NaCl
  • Regenerant flow rate: 2 to 16 m³/hr/m³
  • Regeneration time: 20 to 60 min.
  • Rinse flow rate (Slow): At regeneration flow rate
  • Rinse flow rate (Fast): At service flow rate
  • Rinse Volume: 3 to 5 m³/m³

Testing

Sampling and testing are performed as per standard testing procedures: ASTMD-2187 and IS-7330, 1998.

Packing

  • Super Sack: 1000 lit (35 cft)
  • MS drums: 180 lit.
  • Fiber Drums: 7 cft
  • HDPE lined Bags: 25 lit. (1 cft)

Disclaimer: This data extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.


Preconditioning of Resin:

  1. Load resin in the column and backwash with process water to expand the resin bed by at least 50%-60% for 10 minutes. Allow resin to settle and drain water from the column up to the resin bed level.
  2. Fill the resin column with 2 BV of deionized water and soak for a minimum of 12 hours.
  3. Drain water up to the resin bed level.
  4. Carry out brine regeneration using 8 lbs/cft NaCl as a 6% solution at a 2 BV/hr flow rate. Rinse with demineralized water until the effluent is chloride-free.

Official datasheet (PDF)

Lenntech datasheet mirror

أُعد المحتوى من مراجع تقنية عامة للبحث والمقارنة الأولية. لا يغني الملخص عن ورقة بيانات حالية معتمدة من الشركة المصنعة. تحقق من الإصدارات وحدود التصميم قبل الاستخدام.