Amberlite IRC76

PDF datasheet mirror for Amberlite IRC76 (Rohm & Haas). Verify with OEM before design.

Summary

Product identification

  • Product Name: AMBERLITE IRC76
  • Description: Industrial Grade Weak Acid Exchanger
  • Matrix: Polyacrylic copolymer
  • Functional groups: – COO⁻
  • Physical form: Light yellow opaque beads
  • Ionic form as shipped: H⁺

Properties

  • Total exchange capacity: ≥ 3.90 eq/L (H⁺ form)
  • Moisture holding capacity: 52 to 58 % (H⁺ form)
  • Specific gravity: 1.14 to 1.18 (H⁺ form)
  • Shipping weight: 700 g/L
  • Particle size:
    • Harmonic mean size: 0.50 - 0.75 mm
    • Uniformity coefficient: ≤ 1.9
    • Fine contents (< 0.300 mm): 3.0 % max
    • Coarse beads (> 1.180 mm): 5.0 % max
  • Maximum reversible swelling:
    • H⁺ → Na⁺: 60 %

Suggested Operating Conditions

  • Maximum operating temperature: 100°C
  • Minimum bed depth: 700 mm
  • Service flow rate: 5 to 40 BV*/h
  • Regenerant:
    • HCl:
      • Flow rate: 2 to 8 BV/h
      • Concentration: 2 to 5 %
      • Level: 104 to 110 % of the theory
    • H₂SO₄:
      • Flow rate: 15 to 40 BV/h
      • Concentration: 0.5 to 0.7 %
      • Level: 104 to 110 % of the theory
  • Rinse:
    • Slow rinse: 2 BV at regeneration flow rate
    • Fast rinse: 2 to 4 BV at service flow rate

* 1 BV (Bed Volume) = 1 m³ solution per m³ resin

Performance

AMBERLITE IRC76 is readily regenerated with little over-stoichiometric amounts of strong acids. If sulphuric acid is used, a low concentration (ca 0.7 %) is advised to avoid calcium sulphate precipitation.

Limits of Use

Suitable for industrial uses. For pharmaceutical, food processing, or potable water applications, consult Rohm and Haas.

Hydraulic Characteristics

Figures 1 and 2 in the original document provide data for bed expansion and pressure drop, respectively, as functions of backwash flow rate, service flow rate, and water temperature.