ملخص ورقة البيانات
DIAION UBKN1
PDF datasheet mirror for DIAION UBKN1 (Mitsubishi). Verify with OEM before design.
Summary
Product identification
- Grade Name: DIAION™ UBKN1
- Type: Strong Acid Cation
- Matrix: Styrene-DVB, Gel
- Functional Group: Sulfonic acid
- Ionic Form: H⁺
Typical Properties
- Cross-linkage: 14%
- Shipping Density: 815 g/L
- Particle Density: 1.27 g/mL
- Total Swelling (Na⁺ to H⁺): 5 %
- Whole Bead Count: 95 % min.
- Salt Splitting Capacity: 2.4 meq/mL min.
- Water Content: 37 - 43 %
- Average Diameter: 650 ± 50 μm
- Particle Size Distribution on 850 μm: 0.5 % max.
- Particle Size Distribution 425 - 850 μm: 99 % min.
- Particle Size Distribution thr. 425 μm: 2 % max.
- Uniformity Coefficient: 1.2 max.
- Ionic Conversion (H⁺): 99 % eq% min.
- Ionic Conversion (Na⁺): 0.1 % eq% max.
- Metal Content (Ca): 50 mg/L max.
- Metal Content (Pb): 10 mg/L max.
- Metal Content (Fe): 50 mg/L max.
- Metal Content (Cu): 10 mg/L max.
- Water Extractables: 0.1 g/L-R max.
- Batch Extractable TOC: 10 mg/L max.
Recommended Operating Conditions
- Maximum Operating Temperature: 120 ℃
- Operating pH Range: 0 - 14
- Minimum Bed Depth: 800 mm
- Service Flow Rate: 10 - 40 m/h
Regeneration
- Regenerant: HCl or H₂SO₄
- Regenerant Concentration:
- HCl: 4 - 10 %
- H₂SO₄: 1 - 4 %
- Regenerant Level: 30 - 150 g/L
- Regenerant Flow Rate: 2 - 10 m/h
- Total Rinse Requirement: 2 - 10 BV
Hydraulic Characteristics
The approximate pressure drop at various temperatures and flow rates for each meter of bed depth is shown in the graphs in the official PDF.