ملخص ورقة البيانات
LEWATIT® CNP-LF
PDF datasheet mirror for LEWATIT® CNP-LF (Lanxess LEWATIT). Verify with OEM before design.
Summary
Product identification
Lewatit® CNP LF is a food-grade, weakly acidic, macroporous cation exchange resin based on crosslinked polyacrylate. It is bead-shaped with a special bead size distribution.
Applications:
- Cartridges for household filter systems in combination with activated carbon.
- Decarbonisation and softening of drinking water (in hydrogen form).
- Decarbonisation of drinking water and liquids used as foodstuffs or in foodstuff production.
Physical and Chemical Properties
- Ionic form as shipped: H⁺
- Functional group: carboxylic acid
- Matrix: crosslinked polyacrylate
- Structure: macroporous
- Appearance: yellow, opaque
- Uniformity Coefficient: max. 1.8
- Bead size: > 90 % are between 0.315 - 1.6 mm
- Effective size: 0.4 ± 0.08 mm
- Bulk density: 750 g/l (± 5 %)
- Density: approx. 1.19 g/ml
- Water retention: 45 - 50 wt. %
- Total capacity: min. 4.3 eq/l
- Volume change (H⁺ --> Ca²⁺): max. 7 vol. %
- Stability (pH range): 0 - 14
- Storability (months): max. 6
- Storability (temperature range): -20 - 40 °C
Recommended Operating Conditions
- Operating temperature: max. 75 °C
- Operating pH-range: 5 - 14
- Bed depth: min. 800 mm
- Specific pressure drop (15 °C): approx. 1.3 kPa·h/m²
- Pressure drop: max. 250 kPa
- Linear velocity (backwash, 20 °C): approx. 12 - 14 m/h
- Bed expansion (20 °C, per m/h): approx. 4 vol. %
- Freeboard (backwash, external/internal): 60 - 80 vol. %
Regeneration (Counter Current):
- Regenerant: HCl or H₂SO₄
- Level: approx. 70 g/l HCl or 90 g/l H₂SO₄
- Concentration: 3 - 6 wt. % HCl or 0.5 - 0.8 wt. % H₂SO₄
Regeneration (Co Current):
-
Regenerant: HCl or H₂SO₄
-
Level: approx. 70 g/l HCl or 90 g/l H₂SO₄
-
Concentration: approx. 3 - 6 wt. % HCl or 0.5 - 0.8 wt. % H₂SO₄
-
Linear velocity (regeneration): approx. 5 - 20 m/h
-
Linear velocity (rinsing): approx. 5 - 20 m/h
-
Rinse water requirement (slow/fast): approx. 3.5 BV
Additional Information & Regulations
- Safety: Observe the safety data sheet for product description, transport, storage, handling, safety, and ecology.
- Disposal: Dispose according to European waste nomenclature in the European Community.
- Storage: Store above freezing point, under roof, in dry conditions, away from direct sunlight. If frozen, thaw gradually at ambient temperature before handling or use.
Disclaimer: Extraction may miss figures, footnotes, or revisions; contractual data must match the OEM PDF revision used on the project.