العودة إلى DuPont
DuPont logo

ملخص ورقة البيانات

AmberLite 600BB

PDF datasheet mirror for AmberLite 600BB (DuPont). Verify with OEM before design.

Summary

Product identification

  • Product Name: DuPont™ AmberLite™ 600BB Inert Resin
  • Type: Interface separator buffer beads
  • Form No.: 45-D04716-en, Rev. 1 (April 2025)

Applications

  • Regenerable mixed beds in CPP operation in the power industry
  • Ultra-Pure water polishing for the semiconductors industry
  • Industrial Utility Water 3 components polishing mixed bed

Description

DuPont™ AmberLite™ 600BB is a non-functionalized, spherical inert resin designed for use in mixed beds as "Buffer Beads." Its density and particle size are precisely controlled to achieve a terminal settling velocity between that of cation and anion exchange resins. This creates an inert zone that collects regenerants, minimizing cross-regeneration and thereby improving water quality and reducing rinse times in both internally and externally regenerated mixed bed systems. It is particularly recommended for condensate polishing in the power generation industry and other high-purity mixed bed applications requiring the highest effluent purity.

Typical Properties

Physical Properties

  • Copolymer: Acrylic
  • Matrix: Gel
  • Functional Group: Inert
  • Physical Form: White, translucent to milky, spherical beads
  • Particle Density: 1.10 – 1.16 g/ml
  • Shipping Weight: 650 g/L

Particle Size

  • Particle Diameter: 600 - 750 µm
  • Uniformity Coefficient: ≤ 1.20
  • Fines (< 425 µm): ≤ 2.0 %
  • Oversized (> 850 µm): ≤ 2.0 %

Stability

  • Temperature Range (H⁺ form): 5 – 150°C (41 – 302°F)
  • pH Range (Stable): 0 – 14

Hydraulic Characteristics

Estimated bed expansion and pressure drop are illustrated in figures within the original document, dependent on backwash/service flowrate and temperature.

  • Backwash Expansion: Figure 1 shows estimated bed expansion as a function of backwash flowrate and temperature (10 – 60°C / 50 – 140°F).
  • Pressure Drop: Figure 2 shows estimated pressure drop as a function of service flowrate and temperature (10 – 60°C / 50 – 140°F). These values are for clean water at the start of a service run.

Disclaimer: Extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

Lenntech datasheet mirror

أُعد المحتوى من مراجع تقنية عامة للبحث والمقارنة الأولية. لا يغني الملخص عن ورقة بيانات حالية معتمدة من الشركة المصنعة. تحقق من الإصدارات وحدود التصميم قبل الاستخدام.