ملخص ورقة البيانات
Titromat TH
Engineering summary from PDF text extraction for Titromat TH. Verify every value with the OEM datasheet.
Summary
Product identification
Titromat® TH is used for automatically determining and monitoring the carbonate hardness for high hardness measuring ranges.
Application
- drinking water production and supply
- raw water monitoring
Operating limits
Measuring range
- 2.5–50.0 °dH (resolution: 2.5)
Feed water
Operating pressure
- 1 to 8 bar (15 to 116 psi)
- 0.3 to 1 bar (5 to 15 psi), after removing of the valve body out of the regulator/filter housing
Water inlet
- Opaque hose with 6 mm external diameter / 4 mm internal diameter
Water outlet
- Hose with 6 mm external diameter / 4 mm internal diameter
Water temperature
- 10 to 40 °C (50 to 104 °F)
Electrical
- Power supply: 230–240 VAC, 115 VAC, 24 VAC (all 50–60 Hz)
- Power consumption: max. 30 VA
- Protection class: I
- Degree of protection: IP 65
Mechanical / hydraulic
- Dimensions (W x H x D): 380 x 480 x 280 mm
- Weight: approx. 9.5 kg
- Ambient temperature: 10–45 °C (50 - 104 °F)
- Menu languages: German, English, French, Italian (others upon request)
Disclaimer: Extraction may miss figures, footnotes, or revisions; contractual data must match the OEM PDF revision used on the project.