ملخص ورقة البيانات
Testomat 2000 Fe
Engineering summary from PDF text extraction for Testomat 2000 Fe. Verify every value with the OEM datasheet.
Summary
Product identification
The Testomat 2000® Fe is a wet-chemical online monitor for the photometric analysis of iron content.
Operating limits
- Ambient temperature: 10–45 °C (50 - 104°F)
- Water temperature: 10 to 40 °C (50 to 104°F)
Feed water
- Operating pressure: 1 to 8 bar (15 to 116 psi) or 0.3 to 1 bar (5 to 15 psi) (after removing the valve body from the regulator/filter housing)
- Water inlet: Opaque hose with 6 mm external diameter / 4 mm internal diameter
- Water outlet: Hose with 6 mm external diameter / 4 mm internal diameter
Product water
Not specified.
Electrical
- Power supply: 230–240 VAC, 115 VAC, 24 VAC (all 50–60Hz)
- Power consumption: max. 30 VA
- Protection class: I
- Degree of protection: IP 65
Mechanical / hydraulic
- Dimensions (W x H x D): 380 x 480 x 280 mm
- Weight: approx. 9.5 kg
- Menu languages: German, English, French, Italian, Polish (others upon request)
- Option: Booster pump (see accessories)
Measurement
- Parameter: Iron-II and Iron-III
- Measuring range:
- 0.00 - 0.65 mg/l (resolution of 0.01)
- 0.7 - 1.0 mg/l (resolution of 0.1)
Disclaimer: This summary is based on the provided text extraction. It may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.